"DP UkrGasTech" LTD

+38 (044) 492-76-21, +38 (044) 334-73-03 dpugt@ukrgas.tech, dpugt@dgt.com.ua

USK-OD (PSK-OD) complexes interface device

  • Home
  • USK-OD (PSK-OD) complexes interface device

CONJUGATION DEVICE FOR USK-OD (PSK-OD) COMPLEXES

PURPOSE

( full specifications are in the manual for the device )

1. The USK-OD (PSK-OD) complex interface device is designed for ensuring the exchange of information with measuring complexes for commercial accounting of gas consumption (FLOUTEC-TM type), odorization complexes FLOUTEC-TM-D gas, ACS GRS, gas heaters, as well as the issuance of information about the current gas consumption in the form of pulses.
2. The USK-OD (PSK-OD) complex interface device is not a measuring instrument.
3. The device USK-OD (PSK-OD) is intended for operation in rooms outside explosive zones at a temperature ambient air from minus 40 to plus 60 °C.

TECHNICAL DETAILS

1. The number of formed information access channels . . . – 1
2. Number of directly connected measuring complexes addressed via access channels to the device – 254
3. The speed of digital information exchange over the access channel – from 1200 to 57600 bps
4. Type of serial communication interface used – RS232
5. Number of pulse outputs . . . – 2
• isolated pulse output parameters:
   – switched current. . . – no more than 1 A
   – voltage . . . . . . . . . . – no more than 30 V
• parameters of pulse output of open collector type:
   – switched current – no more than 100 mA
   – voltage . . . . . . . . . . – no more than 33 V
6. The device is powered by external DC source with output voltage from 8 to 24 V (nominal – 12 V)
7. Own current consumption:
   – in standby mode – no more than 25 mA
  – in the mode of information exchange . . . – no more than 75 mA
8. Power consumption at rated supply voltage . . . – no more than 1.5 W
9. Overall and connecting dimensions do not exceed – 157 x 95 x 58 mm
10. Weight USK-OD (PSK-OD) . . . . . – no more than 0.4 kg
11. Device lifespan . . . . . – at least 12 years old
12. The company provides warranty service for PSK-OD (USK-OD) within 24 months and after-sales service during the entire period services.

INSTALLATION & SERVICE

1. The interface device of USK-OD (PSK-OD) complexes is made in plastic housing with brackets for mounting on a DIN rail.
2. The USK-OD (PSK-OD) complex interface device has a built-in self-restoring polymer fuse of the “Polyswitch” type for 120 mA.
3. Changing the settings of access channels (priority, addressing, exchange rate) is carried out using a special device configuration applications.
4. Connectors for external connections – type “Combicon”.

DOCUMENTATION  (Manual)

USK-OD (PSK-OD) complexes interface device
Maintenance program USK-OD (PSK-OD) complex interface device
Description of the PLC09VP_PC program (see page 12, Appendix B of the guide for USK-OD (PSK-OD)

SOFTWARE

I. Configuration of PSK, PSK-OD (USK, USK-OD) is performed in two stages in order:
1. plc08pc5.7z – Configuration program Information access devices PSK, PSK-OD (USK, USK-OD).
  2. PLC09VP_PC.7z – Configuration program Information access devices PSK-OD (USK-OD).
PLC09VP_PC.pdf – Configuration program Information access devices PSK-OD (USK-OD).
Program for configuring Data access devices PSK, PSK-OD (USK, USK-OD, ARBITR) WinConArb. Operator’s manual.
readme.txt – Commentary on the Information Access Device PSK, PSK-OD (USK, USK-OD, ARBITR, ARBITR-OD).