PURPOSE
( full specifications are in the manual for the device )
1. The SH/RS232 interface converter is designed to work as a converter and transmit a signal over a dedicated two-wire line in half-duplex mode and a power supply voltage driver for peripheral devices.
2. The converter is not a measuring instrument.
3. Operation The SH/RS232 interface converter is allowed at ambient temperature from minus 40 to plus 60 °С.
TECHNICAL DETAILS
1. Power supply parameters of the SH/RS232 interface converter from an external DC source:
– nominal supply voltage – 12 V
– allowable values from 8 to 16 V (maximum – 27 V, not tested)
– own consumption current. . . . . . – no more than 100 mA
– power consumption. . . . – no more than 1.5 W
2. The converter provides:
– output voltage of the line driver. . . . . . . – from 10 to 22 V
– maximum output current, no more than . . . . . . . – 150 mA
– the number of formed lines for connecting peripheral devices. . . . . . – one
3. Overall dimensions of the transducer do not exceed 120 x 100 x 25 mm
4. The mass of the converter does not exceed – 0.2 kg
5. The service life of the SH/RS232 interface converter is 12 years
INSTALLATION & SERVICE
1. The converter is made in a plastic case with brackets for mounting on a DIN rail. In this case, the converter must be protected from direct exposure to precipitation.
2. The company provides warranty service for the converter within 24 months and after-sales service for the entire service life.
DOCUMENTATION (Manual)